Before you change the parameter settings for MDI PWE = 1 mode, appears Alarm 100 push CAN + RST and you're ready for setting parameters.
Cable data.
For 9 pin serial on PC RJ45 DB9 For 25 pin serial on CNC RJ45 DB 25
5---------------------------------------------------------7
8---------------------------------------------------------4
2---------------------------------------------------------2
7---------------------------------------------------------5
3---------------------------------------------------------3
To DB 25 Pin 6,8,20 Jumper
Setting to PC
Baudrate = 4800 (Must match CNC setting).
Stop bits = 2
Data bit = 7
Parity = Even
Control code = Xon/Xoff
Setting CNC
Fanuc O series
CNC Setting Data
TV ON = 0
ISO = 1
I/O =0
Parameter 0002 = 000000001
0552 = 10 (Baudrate 4800).
Fanuc 6 series
CNC Setting Data
TV CHECK = 0
PUNCH CODE = 1
INPUT UNIT = 0
INPUT DEVICE 1 = 1
INPUT DEVICE 2 = 1
Parameters 306 = *00010*0
311 = 00001001
340 = 2
341 =1
* = Leave this bit set to what is currently
Fanuc 3 series
CNC Setting Data
TV ON = 0
ISO = 1
I/O= 0
Parameters 005 = 00000001
068 = 4800
Fanuc 10/11/12 Series
CNC Setting Data
TV CHECK = 0
PUNCH CODE = 0
INPUT DEVICE =1
INPUT DEVICE = 1
Parameter 5001 = 1
5110 = 1
5111 = 2
5112 = 10
Fanuc 16 / 18 Series
CNC Setting Data
TV CHECK = 0
PUNCH CODE = 1
I/O CHANNEL = 0 (0-3: CHANNEL NO)
TAPE FORMAT = 0
Parameters
0000 = 00000*10
0020 = 0
0100 = 00000000
0101 = 10000001
0102 = 0
0103 = 10
* = Leave this bit set to what is currently.
You interested my other articles